Error when unlocking the safety door
Bosch Rexroth · IndraDrive MPx02
¿Qué significa F3145 ?
This non-fatal safety error indicates a problem encountered during the process of unlocking a safety door or gate, as monitored by the IndraDrive MPx02. This could mean the unlock command was not executed, the feedback was incorrect, or a timeout occurred, preventing safe access.
Causas comunes
- Mechanical fault or binding in the safety door lock mechanism.
- Electrical fault in the safety door lock actuator (e.g., solenoid, motor).
- Incorrect feedback from the safety door lock status switch.
- Wiring issue between the IndraDrive MPx02 and the safety door lock.
- Incorrect parameterization of the safety door unlocking sequence or timing.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Inspect the safety door lock mechanism for any mechanical obstructions, damage, or binding that prevents it from unlocking smoothly.
- 2
Verify the electrical operation of the door lock actuator, checking its power supply and control signals (e.g., 24VDC to unlock).
- 3
Check the feedback signal from the safety door lock status switch to ensure it accurately reflects the lock's state (locked/unlocked).
- 4
Inspect all wiring connecting the IndraDrive MPx02 to the safety door lock and its sensors for damage or loose connections.
- 5
Review safety parameters in the IndraDrive MPx02 related to safety door unlocking sequence and associated timers.