Safety parameters validation error
Bosch Rexroth · IndraDrive MPx02
¿Qué significa F3140 ?
This non-fatal safety error indicates an inconsistency or corruption detected during the validation of safety-related parameters within the IndraDrive MPx02. This means that the configured safety settings are not internally consistent or valid, preventing the safety functions from operating reliably.
Causas comunes
- Corrupted safety parameter set due to power fluctuations or improper saving.
- Incompatible safety parameter values (e.g., a limit greater than a maximum allowable value).
- Firmware mismatch with the current safety parameter set.
- Manual parameter changes that introduced an invalid configuration.
- Internal memory corruption in the safety control section.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Review all safety-related parameters in the IndraDrive MPx02, comparing them against the machine's safety documentation and the drive's manual for consistency and validity.
- 2
Attempt to load a previously saved, known-good safety parameter set.
- 3
Perform a checksum validation of the safety parameters, if such a function is available in the IndraDrive MPx02 diagnostics.
- 4
Ensure the IndraDrive MPx02's firmware is compatible with the version of the safety parameter set being used.
- 5
If manual parameter changes were made recently, revert them or carefully re-enter them ensuring logical consistency.