Error when checking diagnostic output signal
Bosch Rexroth · IndraDrive MPx02
¿Qué significa F3132 ?
This non-fatal safety error indicates an issue during the internal validation of diagnostic output signals by the IndraDrive MPx02's safety control. This means the drive's self-diagnosis of its safety outputs has detected an inconsistency, potentially affecting the reliability of safety-related outputs.
Causas comunes
- Internal hardware fault within the safety module responsible for diagnostic outputs.
- Discrepancy between the commanded state and the actual feedback of a diagnostic output.
- Firmware issues affecting the diagnostic routines of safety outputs.
- Electromagnetic interference causing transient errors in internal signal monitoring.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Perform a power cycle of the IndraDrive MPx02 to reset the safety logic and internal diagnostic systems.
- 2
Verify the integrity of the drive's firmware and update it if a newer, more stable version is available.
- 3
Check for any external connections or loads on diagnostic outputs that might be causing an unexpected feedback condition.
- 4
Inspect the control section of the IndraDrive MPx02 for any visible signs of damage or loose components.
- 5
If the fault persists after these steps, it may indicate an internal hardware defect requiring service by Bosch Rexroth.