Traduciendo...
F3111

Refer. missing when selecting safety related end pos.

Bosch Rexroth · IndraDrive MPx02

¿Qué significa F3111 ?

This non-fatal safety technology error indicates that a safety-related reference or datum is missing when attempting to select a safety-related end position. This prevents the drive from reliably establishing its safe operating limits, impacting safety functions like Safe Limited Position (SLP).

Causas comunes

  • Safety reference point for the axis has not been set or is corrupted.
  • Encoder fault preventing accurate position feedback for safety functions.
  • Incorrect configuration of safety parameters related to reference positions (e.g., S-0-0193, S-0-0194).
  • Problem with the safety encoder or its connection to the IndraDrive MPx02.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify that the safety reference point for the axis has been correctly established and stored according to the machine's commissioning procedure.

  2. 2

    Check the primary and secondary encoder feedback signals for integrity and proper operation.

  3. 3

    Review safety parameters in the IndraDrive MPx02, specifically those defining reference positions and safety limits, to ensure correct configuration.

  4. 4

    Inspect the wiring and connections of the safety encoder for damage, loose terminals, or improper shielding.

  5. 5

    If an external safety PLC is used, verify its programming and communication with the IndraDrive MPx02 regarding reference position management.

Ver todos los códigos en este manual (99)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: Bosch Rexroth IndraDrive MPx02