F2892

Hardware variant not supported

Bosch Rexroth · IndraDrive MPx02

¿Qué significa F2892 ?

The detected hardware variant of the drive or an installed module is not supported by the current firmware. This typically occurs when a new or different hardware version is used with an older or incompatible firmware release. The drive will not be able to operate safely or correctly without compatible firmware.

Causas comunes

  • Firmware version is too old for the installed hardware
  • Hardware is not officially supported by the drive system
  • Incorrect hardware module installed (e.g., wrong revision)
  • Mismatch between control and power section hardware versions
  • Corrupted firmware preventing proper hardware recognition

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify the exact part numbers and revision levels of the IndraDrive MPx02 and all installed option modules by physically inspecting their labels.

  2. 2

    Check the currently installed firmware version of the IndraDrive MPx02 via the drive's display or using Bosch Rexroth IndraWorks diagnostic software.

  3. 3

    Consult Bosch Rexroth documentation (e.g., firmware release notes, compatibility lists) to determine the compatible firmware version for the detected hardware variant(s).

  4. 4

    Review the system's maintenance logs or installation records to identify any recent hardware replacements or upgrades of the drive or its modules.