F2890

Invalid device code

Bosch Rexroth · IndraDrive MPx02

¿Qué significa F2890 ?

The device code detected by the drive is invalid. This code identifies the specific hardware variant or type of the drive or an installed module. An invalid code suggests an incompatibility between hardware components, an incorrectly installed module, or a firmware issue preventing proper device identification. The drive may refuse to operate with unrecognized hardware.

Causas comunes

  • Incompatible hardware module installed
  • Incorrect firmware version for the detected hardware
  • Faulty device identification chip on a module
  • Damaged communication link for device identification
  • Incorrect parameter setting for device type

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Inspect all installed option modules (e.g., communication, I/O, safety) within the IndraDrive MPx02 for correct physical seating and secure latching/screw connections.

  2. 2

    Verify the compatibility of all installed hardware components and option modules with the specific IndraDrive MPx02 type and its current firmware version using Bosch Rexroth documentation.

  3. 3

    Check the current firmware version of the IndraDrive MPx02 via the HMI or diagnostic software and compare it with the recommended version for the installed hardware configuration.

  4. 4

    Verify drive parameters related to hardware identification, module configuration, or device codes for correct and consistent settings in the drive controller.