F2019

Motor overtemperature shutdown

Bosch Rexroth · IndraDrive MPx02

¿Qué significa F2019 ?

This non-fatal error indicates that the motor connected to the IndraDrive MPx02 has reached an unsafe operating temperature, triggering a protective shutdown. This prevents damage to the motor windings and insulation, ensuring motor longevity.

Causas comunes

  • Motor overloaded, drawing excessive current and generating heat.
  • Insufficient cooling for the motor (e.g., blocked fan, dirty fins, high ambient temperature).
  • Motor cable resistance too high, causing voltage drop and additional heating.
  • Incorrect motor thermal model parameters in the IndraDrive MPx02 (e.g., P-0-0402).
  • Faulty motor temperature sensor (e.g., PTC, KTY) or its wiring.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify the motor loading conditions and reduce the mechanical load if it exceeds the motor's continuous rating.

  2. 2

    Check the motor's cooling system, including its fan, fan cover, and cooling fins, ensuring they are clean and unobstructed.

  3. 3

    Measure the current drawn by the motor during operation and compare it to the motor's nameplate Full Load Amps (FLA).

  4. 4

    Inspect the motor temperature sensor wiring for damage, loose connections, or incorrect termination at the IndraDrive MPx02.

  5. 5

    Check IndraDrive MPx02 parameters related to motor thermal monitoring (e.g., P-0-0402 'Motor overtemperature threshold') and adjust if necessary, ensuring they match the motor's characteristics.