F2005

Cam shaft invalid

Bosch Rexroth · IndraDrive C Drive Controllers

¿Qué significa F2005 ?

The configured cam shaft profile or parameters are invalid, incomplete, or corrupted. This prevents the drive from executing cam-based motion profiles.

Causas comunes

  • Invalid data or format in the cam shaft table.
  • Incorrect number of cam points or interpolation parameters.
  • Memory corruption affecting the cam shaft data.
  • Attempting to activate a cam shaft that has not been properly defined or loaded.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify the cam shaft table data, including the number of points, interpolation methods, and segment definitions, against the application requirements.

  2. 2

    Reload the cam shaft profile into the drive controller to correct any potential data corruption.

  3. 3

    Check parameters related to cam shaft selection and activation to ensure the correct cam is being referenced.

  4. 4

    Consult the programming manual for correct cam shaft definition and parameterization procedures.