E8058

Drive system not ready for operation

Bosch Rexroth · IndraDrive C Drive Controllers

¿Qué significa E8058 ?

The drive system is not in a ready state to accept commands or operate the motor. This can be due to pending errors, incomplete initialization, or unfulfilled safety conditions.

Causas comunes

  • One or more prerequisite conditions for operation (e.g., power-on, safety circuit closed, homing) are not met.
  • Internal errors or warnings within the drive controller preventing readiness.
  • Communication issues with the master controller (PLC) preventing the ready signal.
  • Incorrect drive configuration or parameter settings.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check for any other active fault codes or warnings that might be preventing the drive from achieving readiness.

  2. 2

    Verify that all safety circuits (e.g., Emergency Stop, Safe Torque Off) are closed and conditions are met.

  3. 3

    Check the status of the master communication (fieldbus) and ensure the drive is receiving valid commands.

  4. 4

    Cycle power to the drive controller to force a complete re-initialization.

Ver todos los códigos en este manual (66)