Current limit active
Bosch Rexroth · IndraDrive C Drive Controllers
¿Qué significa E8041 ?
The motor current has reached its configured limit, indicating that the drive is trying to deliver maximum current but may not be able to achieve the commanded torque or speed due to load conditions.
Causas comunes
- Motor running under excessive mechanical load, causing it to reach its current limit.
- Current limit parameter set too low for the application requirements.
- Mechanical binding or obstruction in the system, increasing required current.
- Drive parameter for current limit incorrectly set.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify the mechanical load on the motor and ensure it is within the continuous current capability of the motor and drive.
- 2
Check the drive's current limit parameter and adjust if necessary, ensuring it is appropriate for the application.
- 3
Inspect the mechanical system for any binding, misalignment, or excessive friction that could increase the required current.
- 4
Monitor the actual motor current and torque values during operation to understand the load conditions.