Traduciendo...
E8040
Torque/force actual value limit active
Bosch Rexroth · IndraDrive C Drive Controllers
¿Qué significa E8040 ?
The actual torque or force developed by the motor has reached its configured limit. This warning indicates that the motor is operating at its maximum allowed output for torque/force.
Causas comunes
- Motor running under excessive mechanical load, causing it to reach its torque limit.
- Torque limit parameter set too low for the application requirements.
- Mechanical binding or obstruction in the system, increasing required torque.
- Drive parameter for current/torque limit incorrectly set.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify the mechanical load on the motor and ensure it is within the continuous torque capability of the motor and drive.
- 2
Check the drive's torque limit parameter and adjust if necessary, ensuring it is appropriate for the application.
- 3
Inspect the mechanical system for any binding, misalignment, or excessive friction that could increase the required torque.
- 4
Monitor the actual motor current and torque values during operation to understand the load conditions.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Bosch Rexroth IndraDrive C Drive Controllers