Traduciendo...
E8028

Overcurrent in power section

Bosch Rexroth · IndraDrive C Drive Controllers

¿Qué significa E8028 ?

The current flowing through the drive's power section has exceeded its maximum safe limit. This is a critical warning that indicates an immediate risk of damage to the drive or motor.

Causas comunes

  • Short circuit in the motor windings or motor power cables.
  • Motor or mechanical system experiencing a severe overload or mechanical blockage.
  • Incorrect drive parameters (e.g., motor current limits, control gains) leading to instability.
  • Faulty current measurement circuitry within the drive.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check motor windings and power cables for short circuits or ground faults using appropriate continuity and insulation tests.

  2. 2

    Inspect the mechanical system for any binding, blockage, or excessive friction that could cause high motor current.

  3. 3

    Verify all drive parameters related to motor control, current limits, and load conditions against the motor nameplate and application requirements.

  4. 4

    Monitor the actual motor current during operation to identify when the overcurrent condition occurs.

Ver todos los códigos en este manual (66)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: Bosch Rexroth IndraDrive C Drive Controllers