E2820

Braking resistor overload prewarning

Bosch Rexroth · IndraDrive C Drive Controllers

¿Qué significa E2820 ?

The external braking resistor is reaching its thermal limit due to excessive regenerated energy. Continued operation could lead to resistor damage or a full shutdown.

Causas comunes

  • Excessive braking cycles or too much regenerated energy for the resistor's rating.
  • Braking resistor undersized for the application's duty cycle.
  • Inadequate cooling for the braking resistor.
  • Faulty braking resistor thermal sensor or incorrect parameterization.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the application's braking duty cycle and ensure it is within the braking resistor's specifications. Reduce deceleration times if possible.

  2. 2

    Verify the braking resistor's resistance and power rating against the drive and application requirements.

  3. 3

    Ensure adequate airflow around the braking resistor for cooling and clear any obstructions.

  4. 4

    Check the wiring of the braking resistor's thermal sensor, if present, and verify its functionality.

Ver todos los códigos en este manual (66)