E2055
Feedrate override S-0-0108 = 0
Bosch Rexroth · IndraDrive C Drive Controllers
¿Qué significa E2055 ?
The feedrate override parameter S-0-0108 is set to zero, effectively stopping all motion. This prevents any velocity or position commands from being executed.
Causas comunes
- Feedrate override parameter S-0-0108 was intentionally or accidentally set to 0.
- External PLC or HMI command setting the feedrate override to 0.
- System logic error preventing the override value from being set above 0.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify the value of parameter S-0-0108 (Feedrate override) in the drive controller and ensure it is set to a non-zero value.
- 2
Check the machine's HMI or control program for any active feedrate override settings that might be forced to 0.
- 3
Trace the logic controlling S-0-0108 to ensure no unexpected conditions are setting it to zero.
- 4
If controlled externally, check the master communication for valid override values.
Datos técnicos verificados. Última actualización: March 2026