Traduciendo...
7

Environment Error: Valid temperature difference between μC1 and μC2 exceeded

Beckhoff · EL2912 TwinSAFE

¿Qué significa 7 ?

When LED Diag 1 is off and LED Diag 2 flashes with code 7 (400ms ON / 400ms OFF), it indicates that the temperature difference between microcontrollers μC1 and μC2 has exceeded a valid threshold. This environment error could point to uneven cooling, a sensor malfunction, or an internal fault causing one μC to heat differently than the other, potentially compromising the integrity of dual-channel temperature monitoring.

Causas comunes

  • Significant temperature difference between the two internal microcontrollers (μC1 and μC2).
  • Uneven heat dissipation within the device.
  • Faulty temperature sensors associated with μC1 or μC2.
  • Improper mounting leading to thermal gradients.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Read internal temperature readings for μC1 and μC2 from diagnostic parameters (e.g., P7-01, P7-02).

  2. 2

    Ensure adequate airflow around the device to equalize internal temperatures.

  3. 3

    Verify the integrity of the device's thermal paste or heat sinks.

  4. 4

    Inspect temperature sensor connections if accessible.

Ver todos los códigos en este manual (9)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas