Hardstop Detected

Allen-Bradley · MicroLogix 1400 Programmable Controllers

¿Qué significa 1 ?

This error is generated whenever a hard stop condition is detected by the PTOX subsystem, indicating that a physical limit or emergency stop input has been activated. This error does not fault the controller.

Causas comunes

  • Physical limit switch activation on the controlled axis.
  • External condition triggering a hard stop input to the PTOX subsystem.
  • Incorrect configuration of hard stop monitoring causing false triggers.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Scan the PTOX instruction on a false rung to acknowledge the error condition.

  2. 2

    Reset the EH (Enable Hard Stop) bit to 0 in the PTOX configuration to clear the error.

  3. 3

    Inspect the physical hard stop sensor and its wiring to ensure it is not falsely triggering or stuck in an activated state.

Ver todos los códigos en este manual (60)
Datos técnicos verificados. Última actualización: March 2026