Safety Destination Address Not Valid (V2 CPU)

ABB · PB610 Panel Builder 600 Programming Software

¿Qué significa 1 ?

The safety destination address (F_Dest_Add) is not valid in an AC500 V2 non-safety CPU PM5xx system. This is a critical configuration error preventing safe PROFIsafe communication.

Causas comunes

  • Safety control system cannot find the configured destination PLC address.
  • Network communication issue to the target safety device.
  • Incorrect safety address configured in the V2 CPU parameters.
  • Destination safety device is offline or not powered.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the safety PLC configuration for the "F_Dest_Add" parameter.

Ver todos los códigos en este manual (58)