DriveWorksEZ Fault 2
Yaskawa · GA500 Maintenance and Troubleshooting
What does dWF2 mean?
This fault indicates an issue originating from the DriveWorksEZ program itself, not a drive hardware fault. It signifies a problem with the user-defined logic or configuration which prevents proper program execution on the drive.
Common Causes
- Syntax error or logical inconsistency within the user-programmed DriveWorksEZ sequence.
- Incorrect data type or range assignment for a variable in the DriveWorksEZ program.
- DriveWorksEZ program attempting to access an invalid memory address or non-existent parameter.
- Infinite loop or resource contention within the custom DriveWorksEZ logic causing system hang.
Repair Steps & Checklist
Click steps to track your progress.
- 1
1. Connect to the drive using DriveWorksEZ software and upload the current program.
- 2
2. Review the DriveWorksEZ program code for logical errors, infinite loops, or incorrect variable usage.
- 3
3. Debug the DriveWorksEZ program using simulation mode, observing variable states and program flow.
- 4
4. Verify all parameter references (e.g., P1-01, H1-01) within the DriveWorksEZ logic are valid for the drive model.
- 5
5. Download a previously working version of the DriveWorksEZ program, if available, to isolate the issue to recent changes.