A40100

Alarm at DRIVE-CLiQ Socket X100

Siemens · DAsl Diagnostics and Alarms

What does A40100 mean?

An alarm has been detected at the drive object connected to the DRIVE-CLiQ socket X100. The alarm value (r2124) indicates the first alarm that occurred for this specific drive object. This signals a potential issue with the communication or connected component on this DRIVE-CLiQ interface that requires attention to prevent escalation to a fault or performance degradation.

Common Causes

  • Intermittent or marginal signal quality on the DRIVE-CLiQ connection to socket X100, not yet a complete failure.
  • One of the DRIVE-CLiQ components connected to X100 (e.g., Motor Module, Sensor Module) is reporting an internal warning or non-critical condition.
  • Minor electromagnetic interference (EMI) affecting the communication stability on the X100 link.
  • DRIVE-CLiQ cable for X100 experiencing initial signs of wear, degradation (e.g., slight insulation damage), or loose internal conductors.
  • Parameterization mismatch or configuration warning for the device connected to X100 that does not immediately cause a fault.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Read the alarm value in register r2124 associated with A40100; this will indicate the specific warning or alarm from the connected DRIVE-CLiQ device.

  2. 2

    Power off the drive, then inspect and firmly re-seat the DRIVE-CLiQ cable at both the Control Unit's X100 socket and the connected drive object's (e.g., Motor Module) DRIVE-CLiQ port.

  3. 3

    Check the DRIVE-CLiQ cable for physical integrity, paying close attention to bends, strains, or potential damage points.

  4. 4

    Verify the proper shielding and grounding of the DRIVE-CLiQ cable to minimize external electromagnetic interference.

  5. 5

    Cycle power to the drive system; sometimes transient communication issues or warnings can resolve with a restart.

Browse all codes in this manual (31)
Verified technical data. Last updated: March 2026