232111

Encoder 2: Absolute encoder EnDat, internal fault/error

Siemens · DAsl Diagnostics and Alarms

What does 232111 mean?

The EnDat encoder's internal fault word has set fault bits, indicating a problem with the encoder's internal operation. This could relate to the lighting system, signal amplitude, position value accuracy, or issues with the encoder's power supply (over/undervoltage, overcurrent). The exact fault is detailed in r0949, where each bit represents a specific cause, ranging from a failed lighting system to encoder power supply issues.

Common Causes

  • Internal component failure within the secondary EnDat encoder (Encoder 2), such as degradation of the optical system or sensor array.
  • Low signal amplitude from Encoder 2 detected by its internal diagnostic, potentially due to internal contamination, aging components, or mechanical issues.
  • Checksum errors or inconsistent position data reported by Encoder 2, indicating internal processing errors or data corruption.
  • Operating temperature of Encoder 2 exceeding its specified thermal limits, leading to internal component stress and failure.
  • Intermittent or unstable power supply to Encoder 2, causing unreliable internal operation and communication errors.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Access the drive's diagnostic buffer (r0949 or relevant encoder diagnostic parameter) to determine the specific fault bits reported by Encoder 2 (EnDat fault word).

  2. 2

    Power cycle the machine and observe if the fault clears for Encoder 2; transient internal errors can sometimes be reset by a system restart.

  3. 3

    Verify the supply voltage to Encoder 2 (e.g., at its connector X21) meets the manufacturer's specification (e.g., 5VDC or 24VDC) using a multimeter.

  4. 4

    Inspect the mounting of Encoder 2 and the motor for excessive vibration or mechanical misalignment that could impact encoder longevity and signal quality.

  5. 5

    If the fault persists after power cycling and supply voltage verification, plan for replacement of the secondary EnDat absolute encoder (Encoder 2).

Browse all codes in this manual (31)
Verified technical data. Last updated: March 2026

Related Faults

Source: Siemens DAsl Diagnostics and Alarms