F23.1

Power section – Warning

SEW Eurodrive · MOVIDRIVE system

What does F23.1 mean?

A fault with a 'warning' response has occurred within the power section of the device. This indicates an underlying issue that could degrade drive performance, reduce reliability, and potentially escalate to a full operational fault if ignored.

Common Causes

  • Elevated operating temperature of IGBTs or other power components due to sustained heavy load or inadequate cooling.
  • Minor imbalance in the DC link voltage or current ripple, indicating early signs of capacitor degradation.
  • Transient overcurrents or voltage spikes on the output stage that are near the warning threshold.
  • Internal monitoring circuit detecting a parameter drift (e.g., gate driver voltage) that is not yet critical.
  • Aging or reduced efficiency of the cooling fan operating below optimal speed.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Monitor the drive's internal temperature sensors (e.g., Parameter P7-02, P7-03) and ensure ambient operating temperature is within specification.

  2. 2

    Check the DC link voltage (e.g., Parameter P7-01) for stability and excessive ripple during operation with a multimeter in AC mode.

  3. 3

    Reduce the motor load or adjust acceleration/deceleration ramps (e.g., Parameter P3-04, P3-05) to mitigate transient stress on the power section.

  4. 4

    Visually inspect the power section for signs of discoloration, bulging components, or loose connections on the heatsink.

  5. 5

    Verify the cooling fan is operating at its commanded speed (e.g., Parameter P7-01 or fan speed diagnostics) and not restricted by debris.

Browse all codes in this manual (60)
Verified technical data. Last updated: March 2026

Related Faults

Source: SEW Eurodrive MOVIDRIVE system