F14.24

Travel range exceeded

SEW Eurodrive · MOVIDRIVE system

What does F14.24 mean?

The drive's position for Encoder 2 has exceeded the maximum allowable travel range defined by the current position mode (8382.10). This indicates a configuration error or unexpected machine movement, which can lead to mechanical limits being hit or incorrect positioning.

Common Causes

  • Maximum travel range (P2-15) for Encoder 2 in position mode (8382.10) is set too restrictively, preventing normal machine operation.
  • Incorrect scaling factor (e.g., P2-16 Gear ratio numerator) or feedback resolution (P3-55) for Encoder 2 causing actual position to be misinterpreted.
  • Mechanical overtravel of the machine axis beyond its defined physical limits, triggering the fault before the mechanical end stop.
  • Inaccurate homing procedure for Encoder 2, leading to an incorrect absolute position reference at startup.
  • Uncommanded motion or external force acting on the axis, pushing Encoder 2 beyond its configured travel window.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify and adjust the maximum travel range parameter (P2-15) to accommodate the full mechanical stroke of the axis.

  2. 2

    Check the mechanical limits and end stops of the machine axis to ensure they are physically intact and functioning.

  3. 3

    Re-perform the homing procedure for Encoder 2, ensuring the machine reaches the correct reference position.

  4. 4

    Verify the encoder scaling factors and resolution parameters (e.g., P2-16, P3-55, P3-56) match the machine mechanics and encoder type.

  5. 5

    Monitor the actual position feedback value (e.g., via HMI or drive software) to observe the exact point at which the fault triggers.

Browse all codes in this manual (60)
Verified technical data. Last updated: March 2026