FF0202h
Invalid Axis Selection
SEW Eurodrive · MOVI-PLC SyncCrane Application
What does FF0202h mean?
This fault occurs when an invalid axis number is selected for control. For group control, Process Output Data word PO3 must be set to 99. For single axis control, PO3 must be set to a value between 1 and 8, corresponding to the specific axis.
Common Causes
- An invalid axis identifier was used in a command or configuration.
- Attempting to control an axis that has not been properly initialized or configured.
- Selection of a non-existent or disabled axis in a multi-axis system.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Verify the value of process output data word PO3 (Axis number selection) — ensure it is 99 for group control.
- 2
Verify the value of process output data word PO3 (Axis number selection) — ensure it is a value between 1 and 8 for single-axis control.
Verified technical data. Last updated: March 2026