SLF

MODBUS FAULT

Schindler · Altivar 312 Drive

What does SLF mean?

This fault indicates an interruption in communication on the Modbus bus. It can also be triggered if a remote display terminal is enabled ([HMI command] (LCC) = [Yes] (YES), page 61) but is disconnected.

Common Causes

  • Interruption or break in the Modbus communication bus cabling.
  • Remote display terminal is disconnected while the [HMI command] (LCC) parameter (page 61) is set to [Yes] (YES).

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the physical connections and integrity of the Modbus communication bus.

  2. 2

    Verify the link with the remote display terminal.

  3. 3

    If a remote display is not used, ensure [HMI command] (LCC) is not set to [Yes] (YES).

Browse all codes in this manual (32)
Verified technical data. Last updated: March 2026

Related Faults

Schindler SLF — Fixing: MODBUS FAULT Technical Guide | ErrorLib