Mitsubishi Electric · FR-A800 Variable Speed Drive (Separated Converter)
This fault indicates that the motor speed has exceeded the programmed overspeed detection level in the FR-A800/A800 Plus Series drive. This protective function prevents uncontrolled acceleration or runaway conditions of the motor.
Click steps to track your progress.
Verify the overspeed detection level parameter is correctly set above the maximum expected operating speed but below the motor's absolute maximum safe speed.
Check for external forces acting on the motor/load that could cause overspeed, such as regenerative loads or gravity, and ensure adequate braking or regeneration capacity.
If an encoder is used for speed feedback, verify its functionality and wiring for accurate speed measurement.
Review other speed control parameters (e.g., PID gains, acceleration/deceleration times) to ensure stable operation and prevent speed overshoot.
In applications with external forces, ensure any mechanical brakes or external braking systems are fully functional and properly sized.