EL
ErrorLib
Brands
||
  1. Home
  2. Mitsubishi Electric
  3. FR-A800 Variable Speed Drive (Separated Converter)
  4. E.MB5
About·Privacy·Terms

ErrorLib — Industrial Fault Code Library

Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

Feedback·Support ErrorLib
E.MB5

Brake Sequence Fault

Mitsubishi Electric · FR-A800 Variable Speed Drive (Separated Converter)

What does E.MB5 mean?

This fault indicates an error in the FR-A800's brake sequence control. This typically involves the timing and operation of an external mechanical brake, which is critical for holding the load and safe operation.

Common Causes

  • Mechanical brake failure (e.g., brake not releasing, not engaging, worn pads).
  • Incorrect wiring or malfunction of the brake control circuit (e.g., brake contactor, brake resistor).
  • Improper timing or sequence settings for brake operation (e.g., Pr.1540-Pr.1543 for brake opening/closing timing).
  • Insufficient torque from the motor to hold the load during brake transition.
  • External fault in the brake feedback signal or safety interlock.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify the wiring of the mechanical brake and its control circuit for correct connections and continuity.

  2. 2

    Check the mechanical operation of the brake. Ensure it engages and releases smoothly and completely.

  3. 3

    Review the brake sequence parameters in the FR-A800 (e.g., Pr.1540 Brake opening current detection level, Pr.1541-Pr.1543 for timing settings) and adjust them as needed.

  4. 4

    Measure the current/voltage to the brake coil to ensure it is receiving the correct command.

  5. 5

    Ensure the motor is capable of holding the load at zero speed before the brake releases and after it engages, if direct brake control is used.

Browse all codes in this manual (46)
Verified technical data. Last updated: April 2026

Related Faults

ALM4Output Short-Circuit DetectionE. 1Option FaultE. 13Internal Circuit Fault
Source: Mitsubishi Electric FR-A800 Variable Speed Drive (Separated Converter)
Open Manual (Page 102)Search more codes in this manual