Ackn. force controller error
Kuka · KRC2 KSS System Message
What does 2948 mean?
This is a follow-up message to the 'Force controller error' indicating that the force sensor signal does not match the motion. Error type 1: Actual force changes but position remains constant. Error type 2: Position changes but actual force remains constant. Error type 3: The gun opens further than the position corresponding to FORCE_LIM. These monitoring functions are only active during force control, resulting in dynamic braking, inhibition of active commands, and the 'ALARM_STOP' signal at level 0.
Common Causes
- The force controller has detected an error and acknowledged it.
- Internal fault within the force control loop.
- Parameter misconfiguration affecting the force control algorithm.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Acknowledge the message.
- 2
Check the force sensor for proper operation and signal integrity.
- 3
Check the force sensor cable for damage or loose connections.
- 4
Check the RDC plug-on card for proper installation and functionality.