26118
Mains phase failure, KPP/KSP (axis)
Kuka · KR C4 Operating Instructions
What does 26118 mean?
A failure has been detected in one or more mains input phases supplying the KPP or KSP device for a specific axis. This indicates an issue with the incoming AC power supply to the drive, such as a blown fuse, tripped breaker, or open phase. Loss of a mains phase can cause imbalances, overheating, and prevent the drive from operating.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Inspect the power lead connecting to the KPP for damage, loose connections, or incorrect phasing.
- 2
Inspect all KPP cabling, including input power terminals, for secure connections and integrity.
- 3
Perform a Power Off / Power On cycle of the entire system to reinitialize the drive bus.
- 4
Check the status indicators or diagnostics of the KPP device.
Verified technical data. Last updated: March 2026