26047

Power supply failure, KPP/KSP (axis)

Kuka · KR C4 extended

What does 26047 mean?

The supply voltage to the KPP or KSP module for a specific axis has fallen below 300 V. This indicates an insufficient power supply, potentially causing erratic operation or complete shutdown.

Common Causes

  • Power lead is damaged or disconnected.
  • KPP cabling fault.
  • Supply voltage dropped below 300V.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Inspect the power lead for damage and proper connection.

  2. 2

    Check KPP cabling for damage and correct connections.

  3. 3

    Reinitialize the drive bus: Power Off / Power On.

  4. 4

    Check the KPP module.