57

57 Steer Left Coil Fault

Kone · Elevator Control

What does 57 mean?

A fault has been detected in the steer left coil, indicating an electrical issue with the solenoid responsible for steering left. This disables both lifting and driving functions.

Common Causes

  • Steer left coil open circuit, short circuit, or high resistance.
  • Damaged wiring or loose connections to the steer left coil.
  • Control circuit failure attempting to activate the coil.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify the supply voltage at the steer left coil solenoid terminals against the nominal specification.

  2. 2

    Inspect all wiring and connections leading to and from the steer left coil solenoid for looseness, damage, or corrosion.

  3. 3

    Measure the electrical resistance of the steer left coil solenoid to identify an open circuit or short circuit condition.

  4. 4

    Verify the discrete output signal from the elevator control unit intended to energize the steer left coil solenoid.

Browse all codes in this manual (60)
Verified technical data. Last updated: March 2026