Invalid Prg Command
Indramat · ServoDyn D Servo Drive
What does RS 10 mean?
This serial communication error indicates that the program command transmitted to the CLM01.3-M is invalid. The command is not recognized as part of the valid instruction set documented in Chapter 5, Programming.
Common Causes
- The program command in the serial transmission is unrecognized, misspelled, or does not conform to the correct syntax.
- Attempting to transmit a program command that is not supported by the CLM01.3-M firmware or model.
- Corrupted data during serial transmission leading to an invalid command string.
- Sending device software using an incorrect or outdated command list for the CLM01.3-M.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Verify that the program command being transmitted is listed in Chapter 5 (Programming) and is used correctly.
- 2
Cross-reference the command in the serial transmission against the valid commands listed in Chapter 5.
- 3
Correct any unrecognized or syntactically incorrect commands in the transmitted string.
- 4
Re-transmit the program command after verifying its validity and format.
- 5
Ensure the sending device's software is compatible with the CLM01.3-M's programming instruction set.