18

EOS Cmd Missing

Indramat · ServoDyn D Servo Drive

What does 18 mean?

The "EOS Command Missing" error occurs when the CLM01.3-M user program fails to execute an EOS (End of Synchronization) command where required, specifically at the end of a flying cutoff cycle. This error also triggers if LMD, LML, or LMR commands are encountered before EOS.

Common Causes

  • The EOS command is omitted from the end of a flying cutoff cycle in the user program.
  • LMD (Part Length Via The IDS Board), LML (Part Length), or LMR (Part Length With Registration) commands are executed before the EOS command.
  • A program logic error causes the EOS command to be bypassed or skipped.
  • Corrupted user program data leading to misinterpretation of commands.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify that the EOS command is correctly programmed at the end of every flying cutoff cycle as described in Chapter 5 (Programming).

  2. 2

    Ensure that LMD, LML, or LMR commands are not executed before the EOS command within the program flow.

  3. 3

    Review the user program logic to confirm that the EOS command is always reached and executed at the appropriate point.

  4. 4

    If necessary, explicitly insert the EOS command into the program sequence where it is required.

  5. 5

    Test the flying cutoff cycle thoroughly in both Manual and Automatic modes to ensure correct program sequencing and command execution.