Velocity limit S-0-0091 exceeded
Indramat · Indradrive
What does F8079 mean?
The motor's actual velocity has exceeded the limit defined by parameter S-0-0091 (Maximum Velocity). This fault occurs when the drive detects the motor spinning faster than permitted, potentially due to external forces, incorrect control, or an encoder misread.
Common Causes
- External forces driving the motor beyond the commanded speed (e.g., regenerative load).
- Incorrectly set S-0-0091 parameter, too low for the application.
- Inaccurate encoder feedback indicating a higher speed than actual.
- Control loop instability or incorrect speed command.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Verify the S-0-0091 parameter setting; ensure it is appropriate for the application and motor's maximum safe speed.
- 2
Check for external mechanical forces that might be overdriving the motor.
- 3
Inspect the motor encoder for correct operation and signal integrity; check for noise or damage to the encoder or cable.
- 4
Review the speed command source and ensure it is not erroneously commanding a higher speed.
- 5
Consider re-tuning the speed control loop to ensure stable operation and prevent overshooting the velocity limit.