Autom. commutation: max. motion range
Indramat · Indradrive
What does F8012 mean?
During automatic commutation, the motor exceeded its maximum allowed motion range (either positive or negative direction). This indicates that the drive could not complete the commutation determination within the configured or inherent mechanical movement limits.
Common Causes
- Mechanical blockage or restriction of the motor's shaft.
- Incorrectly configured travel limits or safety limits within the drive parameters.
- Encoder feedback issues leading to inaccurate position detection.
- Overly sensitive settings for motion range monitoring during commutation.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Inspect the mechanical system for any obstructions, binding, or tight spots that prevent the motor from moving freely.
- 2
Review and adjust travel limit parameters (e.g., S-0-0041 Max Travel Limit Positive, S-0-0042 Max Travel Limit Negative) if they are excessively restrictive for the commutation process.
- 3
Check the encoder connections and functionality, ensuring reliable position feedback.
- 4
Verify that the motor has enough clear travel to perform the automatic commutation routine without hitting mechanical stops.
- 5
If applicable, temporarily disable or broaden software travel limits for the commutation process, then re-enable/tighten them afterwards.