Safety related limited increment exceeded
Indramat · Indradrive
What does F7010 mean?
This safety fault indicates that a safety-related monitored increment of position has been exceeded. This is part of safe motion monitoring functions (e.g., Safe Incremental Position) which ensure that the axis does not move more than a defined distance within a specific timeframe or under certain conditions.
Common Causes
- Unexpected or uncontrolled motion of the axis.
- Incorrectly configured safety-related increment limit parameters (e.g., S-0-0XXX Safe Incremental Position Limit).
- Faulty position feedback (encoder) providing incorrect actual position values.
- Mechanical looseness or backlash leading to unintended motion.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Verify the configured safety-related increment limit parameters in the IndraDrive against the safety requirements of the machine.
- 2
Check for any mechanical issues (e.g., play, backlash, loose couplings) that could cause uncontrolled motion.
- 3
Inspect the position encoder for proper operation, secure mounting, and reliable signal output.
- 4
Review the control logic and commands to ensure that no unintended motion commands are being issued.
- 5
Recalibrate the position feedback system if necessary.