F8069

+/-15Volt DC error

Indramat · IndraDrive MPx02

What does F8069 mean?

An error has been detected in the internal +/-15VDC power supply of the IndraDrive MPx02. This internal supply is critical for sensitive control electronics, and its failure results in a fatal error, causing the drive to shut down immediately to prevent further damage.

Common Causes

  • Internal power supply failure within the IndraDrive MPx02.
  • Short circuit on the +/-15VDC internal bus due to faulty components.
  • Contamination or aging of internal components leading to a power supply instability.
  • Overload on an internal auxiliary supply rail.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Completely power cycle the IndraDrive MPx02 by switching off the main supply, waiting for discharge, and then re-applying power.

  2. 2

    Check for any external connections or accessories that might be drawing excessive current from the drive's auxiliary supplies (though +/-15VDC is typically internal).

  3. 3

    Monitor the drive display for other related diagnostic messages after power-up that might pinpoint a more specific issue.

  4. 4

    If the error persists after a power cycle and no external causes are identified, this indicates an internal hardware defect within the IndraDrive MPx02. Contact Indramat service.

Browse all codes in this manual (56)
Verified technical data. Last updated: March 2026

Related Faults