Torque/force command value limit active
Indramat · IndraDrive MPx02
What does E8260 mean?
The torque or force command value issued to the IndraDrive MPx02 is being limited by a configured maximum value. This indicates that the requested torque/force from the master controller exceeds the drive's or application's set limit, and the drive is capping the output.
Common Causes
- The master controller is commanding a torque/force value greater than the configured limit in the IndraDrive MPx02 (e.g., S-0-0092).
- The torque/force limit parameter is set too low for the required application performance.
- An external load or condition requires more torque than commanded, leading to the drive hitting its limit even with a lower command.
- Incorrect scaling factors or units used for torque/force commands between the master and drive.
- A safety function or operating mode has imposed a lower torque limit.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Verify the commanded torque/force value from the master control system (PLC/CNC) and compare it against the drive's configured torque/force limit (e.g., S-0-0092).
- 2
If the application requires higher torque/force, and the motor/drive system can safely provide it, increase the torque/force limit parameter in the IndraDrive MPx02 configuration.
- 3
Assess if the mechanical load is higher than expected, requiring more torque than anticipated by the control program.
- 4
Review any scaling factors or units used for torque/force commands to ensure they are consistent between the master controller and the drive.
- 5
Check if any safety-related torque limitations are active and overriding the standard operating limits.