E8026

Undervoltage in power section

Indramat · IndraDrive MPx02

What does E8026 mean?

This warning signifies that the DC bus voltage within the IndraDrive MPx02's power section has dropped below a specified undervoltage threshold. This can lead to reduced motor performance and, if prolonged, can trigger a fault condition to protect the drive from improper operation.

Common Causes

  • Insufficient incoming AC mains voltage to the drive.
  • Excessive load current demand causing transient DC bus voltage sag.
  • High resistance connections in the power supply path (e.g., loose wires, faulty contactors).
  • Internal DC bus capacitor degradation, reducing its energy storage capacity.
  • Temporary power dip in the mains supply.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Measure the incoming AC mains voltage at the drive input terminals (L1, L2, L3) and confirm it is stable and within the drive's specified operating range.

  2. 2

    Monitor the actual DC bus voltage through the IndraDrive MPx02's diagnostic interface during operation, especially under peak load conditions.

  3. 3

    Inspect all power cable connections, circuit breakers, and contactors in the power supply circuit for tightness and absence of corrosion or damage.

  4. 4

    Reduce the dynamic load on the motor or optimize the motion profile to prevent sudden, large current demands that could cause DC bus sag.

  5. 5

    Verify that the drive's nominal mains voltage parameter (e.g., P-0-0120) is correctly set to match the actual supply voltage.

Browse all codes in this manual (56)
Verified technical data. Last updated: March 2026

Related Faults