Safety related reference missing
Indramat · IndraDrive MPx02
What does E3107 mean?
The IndraDrive MPx02's integrated safety technology is missing a required safety-related reference. This reference could be a specific position, velocity, or direction, which is crucial for safety functions like Safe Operating Stop or Safe Position monitoring. Without it, the safety system cannot guarantee safe operation.
Common Causes
- The axis has not been safely homed or a safety-related reference point has not been established.
- A critical encoder or sensor providing safety-related feedback is not active, has failed, or is incorrectly configured.
- Incorrect parameterization of safety functions that require a validated reference position.
- Loss of absolute position information for safety-related monitoring functions.
- An invalid or unstable signal from a safety-related feedback device.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Ensure that the axis has undergone a successful safety-related homing procedure or that its absolute position reference is established and validated.
- 2
Verify the functionality and wiring of any encoders or sensors designated for safety-related feedback to the IndraDrive MPx02.
- 3
Check the safety configuration parameters to ensure that all required safety references are correctly defined and enabled.
- 4
If using an absolute encoder for safety-related position monitoring, confirm its integrity and that its absolute position data is valid and retained.
- 5
If the issue persists, review the machine's safety concept and the specific requirements for safety-related referencing, then contact Indramat safety service.