Absolute enc. monitoring, measuring encoder (encoder alarm)
Indramat · IndraDrive MPx02
What does E2079 mean?
An alarm condition has been detected by the IndraDrive MPx02 from the absolute measuring encoder (often a linear scale or external rotary encoder directly monitoring the load). This indicates a problem with the primary absolute position feedback for the machine's actual position, impacting precision, homing, and safety functions.
Common Causes
- Loss of absolute position data from the measuring encoder (e.g., battery failure, memory corruption).
- Internal fault within the absolute measuring encoder itself.
- Communication error between the drive and the absolute measuring encoder.
- Incorrect measuring encoder parameterization in the drive for the specific encoder type or resolution.
- Mechanical damage or misalignment of the measuring encoder relative to the axis.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Check the absolute measuring encoder's status indicators (LEDs) for any error codes or abnormal behavior according to its manual.
- 2
Verify the communication wiring and protocol settings between the IndraDrive MPx02 and the absolute measuring encoder, ensuring robust connection.
- 3
If the measuring encoder uses a battery for absolute position retention (e.g., multi-turn rotary), check its voltage and replace it if necessary.
- 4
Ensure that the absolute measuring encoder parameters in the drive are correctly configured for the specific encoder type, resolution, and mounting orientation.
- 5
Attempt a re-initialization of the absolute position or a reference run if the absolute position data has been lost, and if the alarm persists, consider replacing the absolute measuring encoder.