Feedrate override S-0-0108 = 0
Indramat · IndraDrive MPx02
What does E2055 mean?
This warning indicates that the feedrate override parameter S-0-0108 is currently set to zero. A zero feedrate override means that any motion commands will be scaled down to zero velocity, effectively preventing the axis from moving or continuing motion despite active commands.
Common Causes
- Parameter S-0-0108 (Feedrate override) has been intentionally or unintentionally set to 0%.
- External control system (PLC/HMI) is commanding S-0-0108 to 0 due to an active interlock or user input.
- A safety function or interlocking condition in the control program is actively driving the override to zero.
- Incorrect parameter configuration or default value for S-0-0108.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Check the current value of parameter S-0-0108 (Feedrate override) in the IndraDrive MPx02 controller's diagnostic or parameter view.
- 2
Verify the logic in the master control system (e.g., PLC program, HMI) that writes to S-0-0108 to ensure it is not inadvertently setting it to zero.
- 3
Confirm that any active safety or interlocking functions are not commanding a zero override, and that all safety conditions are met for operation.
- 4
Adjust S-0-0108 to a suitable non-zero value (e.g., 100% for normal operation) via the HMI, PLC, or programming tool.