Heatsink overtemp. fault power supply unit
Indramat · DIAX 04
What does F318 mean?
The DIAX04 SSE-03VRS power supply unit's internal heatsink temperature has exceeded its maximum safe operating limit, resulting in a shutdown. This protects the power components from thermal damage. It typically signifies insufficient cooling or sustained overloading of the power supply unit.
Common Causes
- Ambient temperature in the control cabinet is too high for the DIAX04 SSE-03VRS power supply unit.
- Cooling fan on the power supply unit is blocked, dirty, or faulty.
- Heat sink fins of the power supply unit are clogged with dust or debris, impairing heat dissipation.
- The DIAX04 SSE-03VRS power supply unit is overloaded, drawing continuous current beyond its rating.
- Insufficient ventilation or mounting clearances for the power supply unit in the control cabinet.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Allow the DIAX04 SSE-03VRS power supply unit to cool down completely before attempting a reset.
- 2
Inspect the cooling fan on the power supply unit for proper operation, obstructions, and cleanliness.
- 3
Clean any dust or debris from the heat sink fins of the DIAX04 SSE-03VRS power supply unit.
- 4
Verify the ambient temperature in the control cabinet is within the specified operating range.
- 5
Check the load on the power supply unit and ensure it is not continuously exceeding its rated capacity. Reduce load or consider a larger power supply.