231-A094
Drive lock of spindle, tool holder opened
Heidenhain · TNC CNC Controllers
What does 231-A094 mean?
This error indicates that a spindle drive was locked. This occurs when an attempt was made to switch on a spindle drive while the guard door was open AND the tool holder was also open, or due to an internal software error.
Common Causes
- Attempt to switch on a spindle drive while the guard door was open and the tool holder was open.
- Incorrect status reading from the guard door or tool holder sensors.
- Internal software error.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Ensure the guard door is securely closed and locked.
- 2
Confirm that the tool holder is fully closed and locked.
- 3
Check the wiring and functionality of both the guard door sensor and the tool holder sensor for proper operation.
- 4
Verify the software version of the controller and update it if a known issue related to spindle interlocks exists.
Verified technical data. Last updated: March 2026