SKERN-CC%2: Communications error during dynamic sampling of X%4
Heidenhain · TNC CNC Controllers
What does 231-A086 mean?
This error indicates that the dynamic sampling of the EnDat22 encoder (X%4) could not be performed within the prescribed time limit. This is a communication timeout issue, suggesting problems with the encoder, its wiring, or the controller's ability to communicate with it.
Common Causes
- The dynamic sampling of the EnDat22 encoder (X%4) could not be performed within the prescribed time.
- Faulty EnDat22 encoder or damaged encoder cable.
- Timing issues or heavy load on the controller preventing timely communication.
- Electrical interference affecting the EnDat communication.
- Incorrectly configured encoder parameters or communication settings.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Inspect the EnDat22 encoder cable (X%4) for any physical damage, proper shielding, and secure connections.
- 2
Verify the integrity and power supply to the EnDat22 encoder itself.
- 3
Check the controller's diagnostic logs for other concurrent errors that might indicate an overloaded system or internal communication issues.
- 4
Ensure all communication parameters for the EnDat22 encoder are correctly configured according to the manual.
- 5
Test the encoder and its cable separately if possible, or swap components with a known good one if available.