231-A021

Cancelation of brake line test. Guard door open

Heidenhain · TNC CNC Controllers

What does 231-A021 mean?

This error indicates the cancellation of a brake line test. The primary cause is that one or more guard doors were detected as open during either the brake control test or the brake line test, which is a safety interlock violation.

Common Causes

  • Guard door(s) were open during the brake control test or brake line test.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Ensure all guard doors are securely closed and properly latched before initiating and throughout the brake control test or brake line test.

  2. 2

    Verify the correct operation of all guard door safety interlock switches and sensors.

  3. 3

    Inspect the wiring of the guard door safety circuit for damage or loose connections.

  4. 4

    Confirm that all safety circuit components, including interlocks, are functioning correctly and registering the closed state of the doors.