Motor %.1s: t-max incorrect
Heidenhain · NC Control
What does 2194 F110 mean?
The T-MAX (maximum temperature) of the motor for the displayed axis is incorrect. This indicates a configuration issue where the defined maximum temperature limit for the motor does not match its specifications or requirements.
Common Causes
- T-MAX (maximum temperature) parameter for the motor on the displayed axis is incorrectly configured.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Verify the motor's maximum temperature parameter setting (T-MAX) in the NC control for the specified axis against the motor nameplate data.
- 2
Inspect the motor and its cooling system (e.g., fan, heatsink) for blockages, dust accumulation, or any signs of actual overheating.
- 3
Check the motor temperature sensor and its wiring for proper connection, integrity, and functionality.
- 4
Monitor motor load during operation to ensure it is within its continuous rating, as sustained overload can lead to overheating.