U
Inverter: FSSB communication error (COP10B)
Fanuc · Series 30i CNC
What does U mean?
A communication error has occurred on the FSSB (FANUC Serial Servo Bus) via the COP10B connector. This indicates a problem with the COP10B connector or cable, the SVM, or the CNC unit, preventing proper data exchange for servo control.
Common Causes
- Connector or cable (COP10B) failure.
- SVM failure.
- CNC failure.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Inspect the COP10B connector for secure connection and damage.
- 2
Check the COP10B cable for continuity and shorts.
- 3
Verify termination settings on the FSSB bus.
- 4
Check CNC diagnostic screens for further FSSB-related errors.
Verified technical data. Last updated: March 2026
Related Faults
Source: Fanuc Series 30i CNC