P
Communication Error (Amplifier and Module)
Fanuc · Series 30i CNC
What does P mean?
A communication error has occurred between the amplifier and its module. This prevents proper data exchange and control signals, which can lead to system malfunction or inability to operate the connected equipment.
Common Causes
- Defective connector or cable (CXA2A/B) between the amplifier and module
- Defective control printed-circuit board within the amplifier or module
Repair Steps & Checklist
Click steps to track your progress.
- 1
Check the connector and cable (CXA2A/B) for any damage, loose connections, or incorrect routing
- 2
Replace the control printed-circuit board within the affected unit (amplifier or module)
- 3
Replace the SVM unit if the communication error persists after checking cabling and replacing the control board
Verified technical data. Last updated: March 2026
Related Faults
Source: Fanuc Series 30i CNC