F

Inverter: cooling fan stopped of the radiator

Fanuc · Series 30i/31i/32i-MODEL B Plus

What does F mean?

The cooling fan responsible for the inverter's radiator has stopped functioning. Possible causes include the fan not running, a defective fan motor connector or cable, or a failure within the Servo Amplifier. A non-operational radiator fan can lead to critical overheating.

Common Causes

  • Fan not running
  • Fan motor connector or cable defective
  • Servo Amplifier failure

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Inspect the radiator cooling fan for obstructions, debris, or physical damage.

  2. 2

    Verify the fan motor connector and cable for secure connection and electrical continuity.

  3. 3

    If the fan and its cabling are confirmed functional, replace the Servo Amplifier.

Browse all codes in this manual (38)
Verified technical data. Last updated: March 2026

Related Faults

Source: Fanuc Series 30i/31i/32i-MODEL B Plus