SRVO-070
Pulsecoder Serial Data Start/Stop Bit Error
Fanuc · R-30iB Mate + Mate Plus Robot
What does SRVO-070 mean?
The start and stop bits of the serial data received from the Pulsecoder are abnormal. This indicates a communication framing error, often pointing to issues with data transmission integrity, such as signal distortion or timing discrepancies.
Common Causes
- Improper start or stop bit framing in the pulsecoder serial data stream.
- Pulsecoder sending data asynchronously or with incorrect timing.
- Noise or signal degradation affecting the integrity of start/stop bits.
- Faulty pulsecoder unit failing to generate correct serial framing.
- Servo controller expecting a different serial data format.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Ensure the robot connection cable (RMP1, RP1) connector (CRF8) on the 6-Axis servo amplifier and the connector on the motor side are tightly connected.
- 2
Check that the shielding of the robot connection cable (RMP1, RP1) is securely grounded in the cabinet.
- 3
Replace the Pulsecoder.
- 4
Replace the servo amplifier.
- 5
Replace the robot connection cable (RMP1, RP1, RM1).
- 6
Replace the internal cable of the robot (for the Pulsecoder, or for the Motor).
Verified technical data. Last updated: March 2026